Performance power protection with scalable runtime for space-constrained server rooms, and voice and data networks.
| Availability |
| Automatic internal bypass |
Supplies utility power to the connected loads in the event of a UPS overload condition or fault. |
| Scalable runtime |
Allows additional run time to be quickly added as needed. |
| Intelligent battery management |
Maximizes battery performance, life, and reliability through intelligent, precision charging |
| Hot-swappable batteries |
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced |
| Automatic restart of loads after UPS shutdown |
Automatically starts up the connected equipment upon the return of utility power |
| Temperature-compensated battery charging |
Prolongs battery life by regulating the charge voltage according to battery temperature |
| Manageability |
| Network manageable |
Provides remote management of the UPS over the network |
| InfraStruXure Manager Compatible |
Enables centralized management via the APC InfraStruXure® Manager |
| SmartSlot |
Customize UPS capabilities with management cards |
| LED status indicators |
Quickly understand unit and power status with visual indicators |
| Serial Connectivity |
Provides management of the UPS via a serial port |
| Adaptability |
| Plug-and-Play external batteries |
Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS |
| Rack/Tower convertible |
Protects the initial investment in the UPS when migrating from tower to rack-mount environment |
| Flash-upgradeable firmware |
Easy implementation of new firmware upgrades. |
| Serviceability |
| User-replaceable batteries |
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) |
| Automatic self-test |
Periodic battery self-test ensures early detection of a battery that needs to be replaced. |
| Predictive failure notification |
Provides early-warning fault analysis ensuring proactive component replacement. |
| Disconnected battery notification |
Warns when a battery is not available to provide backup power |
| Audible alarms |
Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition |
| Protection |
| Frequency and voltage regulation |
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery |
| Power conditioning |
Protects connected loads from surges, spikes, lightning, and other power disturbances |
| Input power factor correction |
Minimizes installation costs by enabling the use of smaller generators and cabling |
| Generator compatible |
Ensures clean, uninterrupted power to the loads in the event of an extended power outage |
| Cold-start capable |
Provides temporary battery power when the utility power is out |
| Resettable circuit breakers |
Enables a quick recovery from overload events |
| Safety-agency approved |
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals. |