Highly available, redundant and scalable double-conversion on-line power protection
| Availability |
| Modular design |
Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules |
| Configurable for N+1 internal redundancy |
Provides high availabilty through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load |
| Redundant Intelligence Modules |
Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions |
| Hot-swappable intelligence modules |
Ensures clean, uninterrupted power to protected equipment during Intelligence Module replacement |
| Hot-swappable power modules |
Ensures clean, uninterrupted power to protected equipment during Power Module replacement |
| Hot-swappable batteries |
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced |
| Power Modules connected in parallel |
Enhances availability by allowing immediate, seamless recovery from isolated module failures |
| Battery modules connected in parallel |
Delivers higher availability through redundant batteries |
| Automatic internal bypass |
Supplies utility power to the connected loads in the event of a UPS overload condition or fault |
| Automatic restart of loads after UPS shutdown |
Automatically starts up the connected equipment upon the return of utility power |
| Scalability |
| Scalable power capacity |
Reduces UPS over-sizing costs today by allowing quick upgrades later |
| Scalable runtime |
Allows additional run time to be quickly added as needed |
| Plug-and-Play external batteries |
Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS |
| Field-replaceable power distribution panel |
Ensures compatibility with equipment that has different plug types |
| Programmable frequency |
Ensures compatibility with different input frequencies |
| Manageability |
| Manageable external batteries |
Reduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime |
| Network manageable |
Provides remote management of the UPS over the network |
| InfraStruXure Manager Compatible |
Enables centralized management via the APC InfraStruXure® Manager |
| LCD display |
Alpha-Numeric Display which displays system parameters and alarms |
| Intelligent battery management |
Maximizes battery performance, life, and reliability through intelligent, precision charging |
| SmartSlot |
Customize UPS capabilities with management cards |
| Serviceability |
| Predictive failure notification |
Provides early-warning fault analysis ensuring proactive component replacement |
| Automatic self-test |
Periodic battery self-test ensures early detection of a battery that needs to be replaced |
| Audible alarms |
Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition |
| User-replaceable intelligence modules |
Enables simple upgrades and replacements of the Intelligence Modules |
| User-replaceable batteries |
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) |
| Disconnected battery notification |
Warns when a battery is not available to provide backup power |
| Protection |
| Power conditioning |
Protects connected loads from surges, spikes, lightning, and other power disturbances |
| Frequency and voltage regulation |
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery |
| Input power factor correction |
Minimizes installation costs by enabling the use of smaller generators and cabling |
| Generator compatible |
Ensures clean, uninterrupted power to the loads in the event of an extended power outage |
| Cold-start capable |
Provides temporary battery power when the utility power is out |
| Resettable circuit breakers |
Enables a quick recovery from overload events |
| Safety-agency approved |
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals |